99 prosthetic and CAD/CAM references — mini abutment, transfers, analogues, copings, TiBase and screws — with documented S.M.P. codes, hex sizes and torques.

Conexão® line equivalence

Each manufacturer line corresponds to an EFF S.M.P. system, defined by the connection and platform diameter.

Conexão® lineEFF systemConnectionPlatform
Flash Fit (Cone Morse)A3.1Cone Morse CM Ø3.5–5.0Cone Morse 11,5°Rosca Ø1.80 · Plataforma Ø3.5–5.0
Flash Morse Ø3.5K3.2Conical Connection® Ø3.5Cónica internaRosca Ø1.60 · Plataforma Ø3.50 · Implante Ø3.50
Gold Morse (EGM)A3.2Cone Morse Ø3.0 EGMCone Morse EGMRosca Ø1.60 · Plataforma Ø3.00 · Implante Ø3.50–5.00
Hexágono ExternoK1.2Hexágono Externo Ø4.1 RP (Branemark System®)Hexágono ExternoRosca Ø2.00 · Plataforma Ø4.10

Component data sheet

Flash Fit (Cone Morse) · A3.1

O sistema Cone Morse mais difundido do mercado — cobre Neodent CM® e um vasto conjunto de marcas compatíveis.

Prótese parafusada e cimentada

155.05

Tapa Implante

Band: · Torque:

105.05.1A – 105.05.1F

Cicatrizador perfil Ø3.30

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 / 5.5 mm · Torque:

105.05.2A – 105.05.2F

Cicatrizador perfil Ø4.50

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 / 5.5 mm · Torque:

205.05A.1.CJ

Transfer Moldeira Aberta

Band: · Torque:

205.05B.1.CJ / 205.05B.CJ

Transfer Moldeira Fechada (coroa / ponte)

Band: · Torque:

305.05

Análogo Híbrido

Band: · Torque:

405.05A.1 – 405.05A.4

Munhão Provisório coroa Ø3.8

Band: 0.8 / 1.5 / 2.5 / 3.5 mm · Torque: 20 Ncm

405.05B.1 – 405.05B.4

Munhão Provisório ponte Ø4.5

Band: 0.8 / 1.5 / 2.5 / 3.5 mm · Torque: 20 Ncm

805.05.1A.CJ – 805.05.3B.CJ

Coping Plástica base CrCo (coroa / ponte)

Band: 0.8 / 1.5 / 2.5 mm · Torque: 20 Ncm

00500.1A / 00500.1B / 00500.2A / 00500.2B

Kit Munhão Sólido, Transfer e Coping Plástico (cinta 4.0 mm: .1A/.2A · cinta 6.0 mm: .1B/.2B)

Band: 4.0 / 6.0 mm · Torque: 20 Ncm

Pilar múltiplo e unitário

1105.05A.CJ – 1105.05F.CJ

Mini Pilar Reto

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 / 5.5 mm · Torque: 20 Ncm

1105.05.1A.1.CJ – 1105.05.1C.2.CJ

Mini Pilar Angulado 17° (com / sem exact)

Band: 1.5 / 2.5 / 3.5 mm · Torque: 20 Ncm

1105.05.2A.1.CJ – 1105.05.2B.2.CJ

Mini Pilar Angulado 30° (com / sem exact)

Band: 1.5 / 2.5 mm · Torque: 20 Ncm

1105.05.4A.CJ – 1105.05.4F.CJ

Micro Pilar Reto

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 / 5.5 mm · Torque: 20 Ncm

1105.05.1A.CJ – 1105.05.1E.CJ

Pilar GT

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 mm · Torque: 20 Ncm

905.05A.CJ – 905.05E.CJ

EsthetiOne 3.8®

Band: 1.0 / 2.0 / 3.0 / 4.0 / 5.0 mm · Torque: 20 Ncm

CAD/CAM

9105.05A.CJ

Scan Intraoral Titânio

Band: · Torque:

9700.A / 9700.1A

Scan-Body Large / Small

Band: · Torque:

6805.05.5A – 6805.05.4A

Link CAD/CAM TiBase Large / Coroa

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 mm · Torque:

6805.05.1B – 6805.05.4B

Link CAD/CAM TiBase Large / Ponte

Band: 1.5 / 2.5 / 3.5 / 4.5 mm · Torque:

6805.05.5A.S – 6805.05.4A.S

Link CAD/CAM Small / Anti-rotacional

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 mm · Torque:

6805.05.5A.D – 6805.05.4A.D

Link Dinâmico Large / Coroa

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 mm · Torque:

6905.05A

Interface para Zircónia

Band: 1.5 mm · Torque: 20 Ncm

330.01.1L / 330.01.1S

AnálogoLink Large / Small

Band: · Torque:

735.01A / 735.01

Coping Plástico para Link Large / Small

Band: · Torque:

Parafusos

2103.22A.2 / 2103.22A.3

Parafuso Hexagonal (h 0.8–2.5 / 3.5–4.5 mm)

Band: · Torque: 20 Ncm

2103.22F.2 / 2103.22F.3

Parafuso 360° (h 0.8–2.5 / 3.5–4.5 mm)

Band: · Torque: 20 Ncm

2103.09A

Parafuso da Interface para Zircónia

Band: · Torque: 20 Ncm

Flash Morse Ø3.5 · K3.2

Compatível com a conexão cónica Nobel Biocare® NP e equivalentes.

Prótese parafusada e cimentada

155.06

Tapa Implante

Band: · Torque:

105.06A – 105.06C

Cicatrizador perfil reto Ø3.50

Band: 3.0 / 5.0 / 7.0 mm · Torque:

105.06.6A – 105.06.6C

Cicatrizador perfil divergente Ø5.0

Band: 3.0 / 5.0 / 7.0 mm · Torque:

205.06A.CJ

Transfer Moldeira Aberta

Band: · Torque:

205.06B.CJ

Transfer Moldeira Fechada

Band: · Torque:

305.06

Análogo Híbrido

Band: · Torque:

405.06A / 405.06A.1 / 405.06A.2 (coroa) · 405.06B (ponte)

Munhão Provisório — coroa cinta 1.5 / 2.5 / 3.5 mm; ponte apenas cinta 1.5 mm

Band: 1.5 / 2.5 / 3.5 mm (ponte: 1.5 mm) · Torque: 20 Ncm

805.06A.CJ / 805.06A.1.CJ / 805.06A.2.CJ (coroa) · 805.06B.CJ (ponte)

Ucla Plástica base CrCo — coroa cinta 1.5 / 2.5 / 3.5 mm; ponte apenas cinta 1.5 mm

Band: 1.5 / 2.5 / 3.5 mm (ponte: 1.5 mm) · Torque: 20 Ncm

Pilar múltiplo e unitário

1105.06A.CJ – 1105.06D.CJ

Mini Pilar Reto

Band: 1.5 / 2.5 / 3.5 / 4.5 mm · Torque: 20 Ncm

1105.06.1A.CJ / 1105.06.1B.CJ

Mini Pilar Angulado 17°

Band: 2.5 / 3.5 mm · Torque: 20 Ncm

1105.06.2A.CJ / 1105.06.2B.CJ

Mini Pilar Angulado 30°

Band: 3.5 / 4.5 mm · Torque: 20 Ncm

1705.06A – 1705.06C

Pilar Bola

Band: 1.5 / 2.5 / 3.5 mm · Torque: 20 Ncm

905.06A.CJ – 905.06C.CJ

EsthetiOne 3.8®

Band: 1.0 / 2.0 / 3.0 mm · Torque: 20 Ncm

CAD/CAM

9105.06A.CJ

Scan Intraoral Titânio

Band: · Torque:

9700.A / 9700.1A

Scan-Body Large / Small

Band: · Torque:

6805.06A.4 – 6805.06A.3

Link CAD/CAM TiBase Large / Coroa

Band: 0.5 / 1.5 / 2.5 / 3.5 mm · Torque:

6805.06A.1.S – 6805.06A.3.S

Link CAD/CAM TiBase Small / Coroa

Band: 1.5 / 2.5 / 3.5 mm · Torque:

6805.06B.1

Link CAD/CAM TiBase Large / Ponte

Band: 1.5 mm · Torque:

6805.06A.4.D – 6805.06A.3.D

Link Dinâmico Large / Ponte

Band: 0.5 / 1.5 / 2.5 / 3.5 mm · Torque:

6905.06A

Interface para Zircónia

Band: · Torque:

330.01.1L / 330.01.1S

AnálogoLink Large / Small

Band: · Torque:

735.01A / 735.01

Coping Plástico para Link Large / Small

Band: · Torque:

Parafusos

2102.02C

Parafuso Unigrip

Band: · Torque: 20 Ncm

2102.02F

Parafuso 360°

Band: · Torque: 20 Ncm

2102.08C

Parafuso da Interface para Zircónia

Band: · Torque: 32 Ncm

Gold Morse (EGM) · A3.2

Plataforma estreita EGM para implantes Cone Morse Ø3.5 a Ø5.0.

Prótese parafusada e cimentada

155.29

Tapa Implante

Band: · Torque:

105.29.1A – 105.29.1F

Cicatrizador perfil Ø3.30

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 / 5.5 mm · Torque:

105.29.2A – 105.29.2F

Cicatrizador perfil Ø4.50

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 / 5.5 mm · Torque:

205.29A.CJ / 205.29A.1.CJ

Transfer Moldeira Aberta (coroa / ponte)

Band: · Torque:

205.29B.CJ

Transfer Moldeira Fechada

Band: · Torque:

305.29

Análogo Híbrido

Band: · Torque:

405.29A.1 – 405.29A.6

Munhão Provisório

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 / 5.5 mm · Torque: 20 Ncm

805.29A.1.CJ – 805.29A.3.CJ

Ucla Plástica base CrCo

Band: 0.8 / 1.5 / 2.5 mm · Torque: 20 Ncm

00500.1A / 00500.1B / 00500.2A / 00500.2B

Kit Munhão Sólido, Transfer e Coping Plástico (cinta 4.0 mm: .1A/.2A · cinta 6.0 mm: .1B/.2B)

Band: 4.0 / 6.0 mm · Torque:

Pilar múltiplo e unitário

1105.29.3A.CJ – 1105.29.3F.CJ

Pilar EGM Reto Ø4.8

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 / 5.5 mm · Torque: 20 Ncm

1105.29A.CJ – 1105.29F.CJ

Mini Pilar Reto Ø4.8

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 / 5.5 mm · Torque: 20 Ncm

1105.29.4A.CJ – 1105.29.4F.CJ

Micro Pilar EGM Ø3.5

Band: 0.8 / 1.5 / 2.5 / 3.5 / 4.5 / 5.5 mm · Torque: 20 Ncm

1105.29.1A.CJ – 1105.29.1C.CJ

Mini Pilar Angulado 17°

Band: 1.5 / 2.5 / 3.5 mm · Torque: 20 Ncm

1105.29.2A.CJ – 1105.29.2C.CJ

Mini Pilar Angulado 30°

Band: 1.5 / 2.5 / 3.5 mm · Torque: 20 Ncm

905.29A.CJ – 905.29C.CJ

EsthetiOne 3.8®

Band: 1.0 / 2.0 / 3.0 mm · Torque: 20 Ncm

CAD/CAM

9105.29A.CJ

Scan Intraoral Titânio

Band: · Torque:

9700.A / 9700.1A

Scan-Body Large / Small

Band: · Torque:

6805.29A.1 – 6805.29A.4

Link CAD/CAM TiBase Large

Band: 0.8 / 1.5 / 2.5 / 3.5 mm · Torque:

6805.29A.1.S – 6805.29A.4.S

Link CAD/CAM TiBase Small

Band: 0.8 / 1.5 / 2.5 / 3.5 mm · Torque:

6805.29A.1.D – 6805.29A.4.D

Link Dinâmico Large / Coroa

Band: 0.8 / 1.5 / 2.5 / 3.5 mm · Torque:

6905.29A.1

Interface para Zircónia

Band: 0.8 mm · Torque: 20 Ncm

330.01.1L / 330.01.1S

AnálogoLink Large / Small

Band: · Torque:

Parafusos

2102.32E

Parafuso EGM Unigrip

Band: · Torque: 20 Ncm

2102.34E / 2102.34F

Parafuso EGM Ucla / 360°

Band: · Torque: 20 Ncm

2102.41E

Parafuso da Interface para Zircónia

Band: · Torque: 20 Ncm

Hexágono Externo · K1.2

A conexão clássica hexágono externo, com a maior base instalada do mercado e compatibilidade transversal.

Prótese parafusada e cimentada

101.04A – 101.04C

Cicatrizador

Band: 2.0 / 4.0 / 6.0 mm · Torque:

201.04A.CJ

Transfer Moldeira Aberta

Band: · Torque:

201.04B.CJ

Transfer Moldeira Fechada

Band: · Torque:

301.04

Análogo Híbrido

Band: · Torque:

401.04A / 401.04B

Munhão Provisório (coroa / ponte)

Band: · Torque: 32 Ncm

701.04A / 701.04B

Ucla Plástica (coroa / ponte)

Band: · Torque:

801.04A.CJ / 801.04B.CJ

Ucla Plástica base CrCo (coroa / ponte)

Band: · Torque: 32 Ncm

Pilar múltiplo e unitário

1101.04A.CJ – 1101.04D.CJ

Mini Pilar Reto

Band: 1.0 / 2.0 / 3.0 / 4.0 mm · Torque: 32 Ncm

1101.04.1A.CJ – 1101.04.1C.CJ

Mini Pilar Angulado 17°

Band: 2.0 / 3.0 / 4.0 mm · Torque: 32 Ncm

1101.04.2A.CJ / 1101.04.2B.CJ

Mini Pilar Angulado 30°

Band: 3.0 / 4.0 mm · Torque: 32 Ncm

CAD/CAM

9101.04A.CJ

Scan Intraoral Titânio

Band: · Torque:

9700.A

Scan-Body Large

Band: · Torque:

6801.04A.1 – 6801.04A.4

Link CAD/CAM TiBase Large / Coroa

Band: 0.6 / 2.0 / 3.0 / 4.0 mm · Torque:

6801.04B.1

Link CAD/CAM TiBase Large / Ponte

Band: 1.0 mm · Torque:

6801.04A.1.D – 6801.04B.1.D

Link Dinâmico (coroa / ponte)

Band: 0.6 / 1.0 / 2.0 / 3.0 / 4.0 mm · Torque:

6801.04A / 6801.04B

Link CAD/CAM cinta invisível (coroa / ponte)

Band: invisível · Torque:

330.03.1L

AnálogoLink Large

Band: · Torque:

735.01A

Coping Plástico para Link Large

Band: · Torque:

1501.04A / 1501.04A.C

Abutment Rollings (Ti / CrCo)

Band: · Torque:

Parafusos

2104.01A

Parafuso Hexagonal

Band: · Torque: 32 Ncm

2104.01F

Parafuso 360°

Band: · Torque: 32 Ncm

Frequently asked questions about Conexão®

Do EFF components fit Conexão® implants?

Yes. The S.M.P. systems A3.1, K3.2, A3.2, K1.2 reproduce the connection and platform of the Flash Fit (Cone Morse), Flash Morse Ø3.5, Gold Morse (EGM), Hexágono Externo lines from Conexão®, in medical-grade titanium with CE marking.

What torque should I apply to components compatible with Conexão®?

The documented torques for these systems are 20 Ncm, 32 Ncm. Always use a calibrated torque wrench and follow the clinical case protocol.

Are the components original Conexão®?

No. They are compatible EFF components, manufactured independently. Conexão® is a registered trademark of its manufacturer and has no connection with EFF Dental Ibérica.

Is there a mini abutment compatible with Conexão®?

Yes. The Regular Platform Mini Abutment (M.P system) sits on the intermediate abutment and offers the full prosthetic and CAD/CAM line, with a prosthetic torque of 10 Ncm.